Introduction:
Termination of cable
accessories that go along with the cables, used for the purpose of restoring
the damage of cable. Composed mainly of rubber Silicone, fast construction
follows the method of cold / heat Shrink. It is mainly used in
construction,civil and industrial
electric. There are two types of cable (the cold shrink and heat shrink cable) 1. Cold Shrink Terminations Cold Shrink Terminations for MV Cables with or without Armor,
level voltage to 36kV.
Termination made of Silicone Rubber fast method of constructionafter
methord of cold shrink and is designed for all medium-voltage
cables that have a metal shield structure, with or without borders, copper or
aluminum core -Scope of application:
• For medium-voltage
cables up to 36kV
• For insulation cable: polyethylene, XLPE, EPR.
• For 1, 3-core cable, copper tape shield or copper fiber, with or without
armor.
• Conductor core is copper or aluminum.
• Installation in the areas where environmental pollution.
• Used to connect to the switchgear, transformers, motors, bars, overhead
lines... Specification: Termination is used for power cables with constant operating
temperature at 90oC and overload.
at 130oC. Rated current of Termination is equal or exceed the rated current
of the cable used.
Termination built a special class with a high dielectric constant (High-K) to
control the field electric around the cable insulation.
The field electric in the cable just under the High-K will be smaller than the
case cable without High-K class. 2.Heat Shrink Terminations Heat Shrink Terminations for MV Cables with or without Armor,
level voltage to 40.5kV.
Termination made of Silicone Rubber fast method of constructionafter
methord of cold shrink and is designed for all medium-voltage
cables that have a metal shield structure, with or without borders, copper or
aluminum core -Scope of application:
• For medium-voltage cables up to 36kV
• For insulation cable: polyethylene, XLPE, EPDM
• For 1, 3-core cable, copper tape shield or copper fiber, with or without
armor.
• Conductor core is copper or aluminum.
• Installation in the areas where environmental pollution.
• Used to connect to the switchgear, transformers, motors, bars, overhead
lines... Specification: Termination is used for power cables with constant operating
temperature at 90oC and overload.
at 130oC.
Rated current of
Termination is equal or exceed the rated current of the cable used.
Termination built a special class with a high dielectric constant (High-K) to
control the field electric around the cable insulation.
The field electric in the cable just under the High-K will be smaller than the
case cable without High-K classk
10kV 3x95SQ HST Indoor Termination clip. http://www.youtube.com/watch?v=mOntB-qwIFg .